{"title":"Partica LA-970","description":"\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIntegrating laser diffraction with dynamic imaging enables faster, more complete particle characterization. Partica combines these complementary techniques in a single instrument, capturing particle size distribution and shape simultaneously to reduce measurement time, streamline R\u0026amp;D and QC workflows, and save lab space.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"optionnal-dry-cell-window-1pc","title":"Optional Dry Cell Window #3012303172","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003eOptional Dry Cell Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1pc\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e\u003c\/span\u003e The optional dry cell window must be ordered per 2.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003e\u003cspan\u003eMaintenance and replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eVisual checks\u003c\/strong\u003e: Frequently inspect the dry cell window for any signs of damage, such as scratches, cracks, or cloudiness. Clear windows are essential for accurate particle measurement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eCleanliness\u003c\/strong\u003e: Ensure that the window surface is free from dust, fingerprints, and other contaminants. Any obstructions can distort the particle characterization results.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eMinimize touching\u003c\/strong\u003e: Avoid touching the window with bare hands. Use gloves if necessary to prevent oil and dirt from contaminating the surface.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003eSigns for Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eVisible damage\u003c\/strong\u003e: Replace the window if there are visible scratches, cracks, or chips that cannot be polished out or if the window has become cloudy and affects measurement accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePerformance issues\u003c\/strong\u003e: If particle characterization results become inconsistent or unreliable, and other factors have been ruled out, it might be time to replace the window.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e \u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e \u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca style=\"color: #000000;\" title=\"Link to The HORIBA Store LA 960 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\"\u003eLA-960\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca title=\"Link to HORIBA Particle Characterization webpage\" style=\"color: #000000;\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" data-mce-fragment=\"1\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e \u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41676889456825,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/0000044733.png?v=1639994444"},{"product_id":"fraction-cell-with-magnetic-stirrer-1","title":"Fraction Cell 15mL with magnetic stirrer #3200090354","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003eFraction Cell 15mL with magnetic stirrer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThis accessory is ideal when total sample amount is small, the sample or dispersant is toxic or you wish to recover the measurement sample. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 15 mL\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003e\u003cspan\u003eMaintenance and replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eInspect and clean the stirrer\u003c\/strong\u003e: Ensure the magnetic stirrer is clean and free from residues.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eCheck the magnet\u003c\/strong\u003e: Verify that the magnetic stirrer is functioning correctly and the magnet is not demagnetized or damaged.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: #000000;\"\u003eHandle the fraction cell with gloves to prevent oils and other contaminants from affecting the analysis.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eRegularly inspect the fraction cell for any signs of wear, such as scratches, cracks, or cloudiness.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eEnsure that the magnetic stirrer mechanism is working smoothly and efficiently.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePhysical damage\u003c\/strong\u003e: Cracks, scratches, or other damage to the cell that could compromise the integrity of the sample.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePersistent contamination\u003c\/strong\u003e: Residues or contaminants that cannot be removed through cleaning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eMagnetic stirrer malfunction\u003c\/strong\u003e: If the magnetic stirrer is not functioning properly or the magnet is demagnetized, affecting sample mixing.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca style=\"color: #000000;\" href=\"https:\/\/store.eu.horiba.com\/products\/fraction-cell-holder-3200625701\"\u003eFraction Cell Holder #3200022742\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca style=\"color: #000000;\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" data-mce-fragment=\"1\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41676958630073,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/0000050959.png?v=1639994974"},{"product_id":"fraction-cell-10ml-with-magnetic-stirrer-3200090355","title":"Fraction Cell 10mL with magnetic stirrer #3200090355","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003eFraction Cell 10mL with magnetic stirrer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThis accessory is ideal when total sample amount is small, the sample or dispersant is toxic or you wish to recover the measurement sample. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 10 mL\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003e\u003cspan\u003eMaintenance and replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eInspect and clean the stirrer\u003c\/strong\u003e: Ensure the magnetic stirrer is clean and free from residues.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eCheck the magnet\u003c\/strong\u003e: Verify that the magnetic stirrer is functioning correctly and the magnet is not demagnetized or damaged.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: #000000;\"\u003eHandle the fraction cell with gloves to prevent oils and other contaminants from affecting the analysis.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eRegularly inspect the fraction cell for any signs of wear, such as scratches, cracks, or cloudiness.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eEnsure that the magnetic stirrer mechanism is working smoothly and efficiently.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePhysical damage\u003c\/strong\u003e: Cracks, scratches, or other damage to the cell that could compromise the integrity of the sample.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePersistent contamination\u003c\/strong\u003e: Residues or contaminants that cannot be removed through cleaning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eMagnetic stirrer malfunction\u003c\/strong\u003e: If the magnetic stirrer is not functioning properly or the magnet is demagnetized, affecting sample mixing.\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca title=\"Link to The HORIBA Store Fraction Cell Holder webpage\" href=\"https:\/\/store.eu.horiba.com\/products\/fraction-cell-holder-3200625701\" style=\"color: #000000;\"\u003eFraction Cell Holder #3200022742\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca title=\"Link to HORIBA Particle Characterization webpage\" data-mce-fragment=\"1\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" style=\"color: #000000;\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41676963610809,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/0000056879.png?v=1639995066"},{"product_id":"paste-cell-high-viscosity","title":"Paste cell \"High viscosity\" #3200032358","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003ePaste cell \"High viscosity\"\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" title=\"Link to The HORIBA Store LA 9XX Series webpage\" style=\"color: #000000;\"\u003eLA-960\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e \u003ca href=\"https:\/\/www.horiba.com\/details\/la-950-laser-particle-size-analyzer-108\/\" title=\"Link to HORIBA LA 950 Webpage\" style=\"color: #000000;\"\u003eLA-950\u003c\/a\u003e (LY9504)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca title=\"Link to HORIBA Particle Charactierization Basic Principle webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" style=\"color: #000000;\" data-mce-fragment=\"1\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41676996018361,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/0000039407.png?v=1639995335"},{"product_id":"accessory-for-ly-9609-plug-for-cell-a","title":"Accessory for LY-9609: Plug for cell A #3200275149","description":"\u003ch2\u003e\n\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003e\u003cspan\u003eUpgrade your LY-9609: Introducing the Plug for Cell A accessory \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1pc \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e FKM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIn the HORIBA \u003ca title=\"Link to The HORIBA Store LA-960 Series webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" style=\"color: rgb(0, 0, 0);\"\u003eLA-960\u003c\/a\u003e, this accessory is used to plug the sample cells of the \"High concentration\/Low viscosity\" Paste cell (LY-9609) for Cell \"A\".\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIn the HORIBA \u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca title=\"Link to The HORIBA Store SZ-100 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/sz-series-1\" style=\"color: rgb(0, 0, 0);\"\u003eSZ-100\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca title=\"SZ-100 HORIBA\" href=\"https:\/\/store.eu.horiba.com\/collections\/sz-series-1\"\u003e\u003c\/a\u003e, this accessory is used to plug the Disposable Zeta cell.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eOptimize the capabilities of your \u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to HORIBA LY-9609 Accessory Webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/accessories\/products\/ly-9609-high-concentration-cell\"\u003eLY-9609\u003c\/a\u003e with our accessory plug for cell A. This essential component enables seamless connection of cell components, facilitating accurate analysis and reliable results. Enhance your equipment to streamline your research process and increase your productivity. Invest in the Plug for cell A accessory today to unleash the full potential of your LY-9609 and enhance your scientific analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cspan color=\"#000000\"\u003eCompatibility:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca title=\"Link to The HORIBA Store LA-960 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" style=\"color: rgb(0, 0, 0);\"\u003eLA-9xx Series (LA-960)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"LY-9609 Accessory HORIBA\" href=\"https:\/\/www.horiba.com\/fra\/scientific\/products\/detail\/action\/show\/Product\/ly-9609-high-concentration-cell-3556\/\"\u003eL\u003c\/a\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"LY-9609 HORIBA\" href=\"https:\/\/www.horiba.com\/fra\/scientific\/products\/detail\/action\/show\/Product\/ly-9609-high-concentration-cell-3556\/\"\u003eY\u003c\/a\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to HORIBA LY-9609 Accessory Webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/ly-9609-high-concentration-cell-3556\/\"\u003e-9609\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca style=\"color: #000000;\" title=\"Link to HORIBA Particle Characterization Basic Principle Webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\"\u003eParticle Characterization.\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41677032685753,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/0000020040.png?v=1639995643"},{"product_id":"holder-for-feeder-v-chute-type","title":"Holder for feeder \"V Chute\" type #3200090365","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003eHolder for feeder \"V Chute\" type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eYou can find the Feeder \"V chute\" type for Dry module #3200090363 \u003ca style=\"color: rgb(0, 0, 0);\" href=\"https:\/\/store.eu.horiba.com\/products\/feeder-v-chute-type-for-dry-module\" title=\"Link to The HORIBA Store webpage for Feeder V Chute for dry module\"\u003ehere\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eProper maintenance and timely replacement of this component are essential for ensuring efficient and consistent operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eMaintenance and replacement:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eVisual check: \u003c\/strong\u003eRegularly inspect the holder for any signs of wear, cracks, or damage. Look for any deformation, corrosion, or structural issues.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eCheck alignment:\u003c\/strong\u003e Ensure the holder is properly aligned with the V chute and the feeder mechanism. Misalignment can lead to uneven material flow and equipment damage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eSurface cleaning:\u003c\/strong\u003e Use a soft, lint-free cloth to remove dust and debris from the holder. Avoid using abrasive materials that could scratch or damage the holder.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eSafety gear:\u003c\/strong\u003e Wear appropriate safety gear, such as gloves and safety glasses, to handle the holder and surrounding components safely.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eRegular maintenance not only extends the life of the holder but also enhances the overall performance of the equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca style=\"color: #000000;\" href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" title=\"Link to The HORIBA Store LA 960 webpage\"\u003eLA-960\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca title=\"Link to HORIBA Particle Characterization Basic Principle webpage\" style=\"color: #000000;\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" data-mce-fragment=\"1\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41817795166393,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/HolderfeederVchute.png?v=1673427071"},{"product_id":"feeder-v-chute-type-for-dry-module","title":"Feeder \"V chute\" type for Dry module #3200090363","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003eFeeder \"V chute\" type for Dry module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cspan style=\"color: #000000;\"\u003eEnhance your production line efficiency with the Feeder \"V chute\" type, designed for optimal operation in dry processing environments\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eUseful for small amount of material compared to \u003ca href=\"https:\/\/store.eu.horiba.com\/products\/standard-chute-3012317055\" title=\"Link to The HORIBA Store Standard Chute for dry module webpage\" style=\"color: rgb(0, 0, 0);\"\u003eStandard Chute\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eV form chute Dry option. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan\u003eThe Feeder \"V chute\" type for Dry Module is engineered for efficient material handling and precise delivery. Its unique V-shaped design ensures smooth and controlled flow of dry materials, reducing blockages and minimizing waste. Ideal for industrial applications, this feeder offers reliable performance and easy integration into your particle analyzer. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" title=\"Link to The HORIBA Store LA-960 Series webpage\" style=\"color: rgb(0, 0, 0);\"\u003eLA-960\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca title=\"Link to HORIBA LA-950 webpage\" href=\"https:\/\/www.horiba.com\/uploads\/media\/RE09-15-084.pdf\" style=\"color: rgb(0, 0, 0);\"\u003eLA-950\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca data-mce-fragment=\"1\" style=\"color: #000000;\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" title=\"Link to HORIBA Particle Characterization Basic Principle webpage\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":41817799917753,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/3200090363.png?v=1702291404"},{"product_id":"ly-9609-high-concentration-cell","title":"Paste Cell Holder \"High Concentration\/Low Viscosity\" #3200748699","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003ePaste Cell Holder \"High Concentration\/Low Viscosity\" \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThis accessory for the HORIBA \u003ca style=\"color: #000000;\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/partica-la-960v2-1944\/\" title=\"Link to HORIBA Partica LA 960V2 Webpage\" rel=\"noopener\" target=\"_blank\"\u003ePartica LA-960V2\u003c\/a\u003e allows for measurement of high concentration, low viscosity samples. Understand the particle dispersion state of high concentration slurry, such as positive and negative electrode materials of secondary batteries, inks, paints, pigments, emulsions, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eStatic Light Scattering only.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/partica-la-960v2-1944\/\" style=\"color: #000000;\" title=\"Link to HORIBA Partica LA 960V2 Webpage\"\u003ePartica LA-960V2\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\" title=\"Link to The HORIBA Store LA-970 webpage\" style=\"color: rgb(0, 0, 0);\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\" title=\"Link to The HORIBA Store LA-1000 webpage\" style=\"color: rgb(0, 0, 0);\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThe high concentration cell unit allows measurement closer to original concentration with low dilution rates, without dilution and variable concentration.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMeasure without dilution: Inks, paints, pigments, emulsions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003ePositive and negative electrode materials of secondary batteries etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eObserve changes in the agglomeration state based on concentration etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAgglomerated was found when a battery was measured near to original concentration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/static.horiba.com\/fileadmin\/Horiba\/_processed_\/6\/f\/csm_high-concentration-graph_e67ad722f8.jpg\" alt=\"Particle Size Chart HORIBA\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eComparison of the results of undiluted suspension measurement and flow measurement (diluted with dispersant).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIncluding High Concentration Cell Holder (1 pc), High Concentration Cell Frame (1 set), Cell Glass A and B (1 set), 5 and 50 micron Spacer (each 10 pcs), PTFE Plug and FKM Plug (each 2 pcs), Syringe (plastic, 3 ml) (10 pcs), Tweezers (1pc).\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eCan be upgraded after the installation of LA main unit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e1 day of installation\/training must be added\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" style=\"color: #000000;\" title=\"Link to HORIBA Partica Characterization Basic Principle webpage\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":42787195584697,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/files\/Designsanstitre_43.png?v=1709040911"},{"product_id":"paste-cell-holder-high-viscosity-3100196026","title":"Paste Cell Holder \"High concentration\/high viscosity\" #3100196026","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003ePaste cell holder \"High concentration\/high viscosity\" \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan\u003ePaste cell holder \"High concentration\/high viscosity\" \u003c\/span\u003eLY9504 \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"color: #000000;\"\u003efor HORIBA LA-960\/LA-950 (V1\u0026amp;V2).\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan data-teams=\"true\"\u003eStatic Light Scattering only.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan data-teams=\"true\"\u003eCan be upgraded after the installation of LA main unit.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan data-teams=\"true\"\u003e1 day of installation\/training must be added.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan data-teams=\"true\"\u003eNo Paste Cell \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca href=\"https:\/\/store.eu.horiba.com\/products\/paste-cell-high-viscosity\" title='Link to The HORIBA Store Paste cell \"High viscosity\" Webpage' style=\"color: rgb(0, 0, 0);\"\u003e3200032358\u003c\/a\u003e\u003c\/span\u003e included.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca href=\"https:\/\/www.horiba.com\/details\/la-950-laser-particle-size-analyzer-108\/\" title=\"Link to HORIBA LA 950 webpage\" style=\"color: #000000;\"\u003eLA-950 (V1\u0026amp;V2)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca href=\"https:\/\/www.horiba.com\/fra\/scientific\/products\/detail\/action\/show\/Product\/partica-la-960v2-1944\/\" title=\"Link to HORIBA LA 960 webpage\" style=\"color: #000000;\"\u003eLA-960 (V1\u0026amp;V2)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eCan be upgraded after the installation of LA main unit\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca title=\"Link to HORIBA Particle Charactierization Basic Principle webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" style=\"color: #000000;\"\u003eParticle Characterization\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":42787399041209,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/products\/3100196026.png?v=1702395047"},{"product_id":"fraction-cell-5ml-3200219234","title":"Fraction Cell 5mL #3200219234","description":"\u003ch2\u003e\u003cspan style=\"color: #478cd0;\"\u003e\u003cstrong\u003eFraction Cell 5mL\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eFraction cell No magnetic stirrer 5 mL for HORIBA \u003ca href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" title=\"Link to The HORIBA Store LA-960 webpage\" style=\"color: rgb(0, 0, 0);\"\u003eLA-960\/LA-950\u003c\/a\u003e (V1\u0026amp;V2) (LY-9501)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eProper maintenance and timely replacement of the Fraction Cell are essential to ensure accurate particle size measurements and the overall longevity of the instrument.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eMaintenance and replacement:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePost-analysis cleaning\u003c\/strong\u003e: After each use, immediately clean the fraction cell to remove any sample residues.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eHandle the fraction cell with clean gloves to avoid transferring oils and other contaminants from your hands.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eRegularly inspect the fraction cell for any signs of wear, such as scratches, cracks, or cloudiness that could affect the accuracy of measurements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003ePeriodically verify the performance of the fraction cell by running standard samples with known particle size distributions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eSigns Indicating Replacement\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePhysical damage\u003c\/strong\u003e: Cracks, scratches, or other physical damage to the cell that could compromise sample integrity and measurement accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003ePersistent contamination\u003c\/strong\u003e: If residues or contaminants persist despite thorough cleaning, the cell may need to be replaced.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eMeasurement inconsistencies\u003c\/strong\u003e: If standard samples yield inconsistent results or if there are significant deviations in measurements, it might indicate that the fraction cell is deteriorating.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #478cd0;\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" style=\"color: #000000;\" title=\"Link to The HORIBA Store LA-960 Webpage\"\u003eLA-9xx Series\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eIf you want more information about this topic, please visit our website on \u003ca data-mce-fragment=\"1\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/particle-characterization\/\" style=\"color: #000000;\" title=\"Link to The HORIBA Store Particle Characterization Basic Principle Webpage\"\u003eParticle Characterization\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":43063547723961,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/files\/Designsanstitre_26.png?v=1707841956"},{"product_id":"cotton-tipped-swab-3200043978","title":"Cotton-tipped swab #3200043978","description":"\u003ch2\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eCotton-tipped swab\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e Set of 100 pieces\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eFor single use only\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca title=\"Link to The HORIBA Store LA-350 instrument webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/la-3xx-series-1\" style=\"color: rgb(0, 0, 0);\"\u003eLA-350\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIf you want more information about this topic, please visit our website on \u003ca title=\"Link to HORIBA Partica Mini webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/partica-mini-la-350-830\/\" style=\"color: rgb(0, 0, 0);\"\u003ePartica mini LA-350 – Portable Routine Laser Diffraction Analyzer - HORIBA\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":49891465363783,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/files\/3200043978Applicator_x100piecesperset.jpg?v=1750776825"},{"product_id":"standard-chute-3012317055","title":"Standard chute for dry module #3012317055","description":"\u003ch2\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eStandard chute for dry module (U-chute)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eOne included with \u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store PowderJet Dry Feeder System\" href=\"https:\/\/store.eu.horiba.com\/products\/powderjet-dry-feeder-system\"\u003eDry PowderJet Dry feeder Unit\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eMaintenance and replacement:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eCleaning:\u003c\/strong\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eAfter each use, clean the chute to prevent sample residue buildup.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-end=\"508\" data-start=\"494\"\u003eInspection\u003c\/strong\u003e: Periodically inspect the chute for signs of wear, corrosion, or damage. Any irregularities can affect sample flow and measurement accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-end=\"652\" data-start=\"639\"\u003eAlignment\u003c\/strong\u003e: Ensure that the chute is properly aligned with the sample introduction system to prevent spillage or misdirection of samples.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" href=\"https:\/\/store.eu.horiba.com\/collections\/la-9xx-series-1\" title=\"Link to The HORIBA Store LA 9XX Series webpage\"\u003eLA-960\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" aria-describedby=\"a11y-new-window-message\" rel=\"noopener\" href=\"https:\/\/www.horiba.com\/details\/la-950-laser-particle-size-analyzer-108\/\" title=\"Link to HORIBA LA 950 Webpage\" target=\"_blank\"\u003eLA-950 (LY 9505 230V).\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIf you want more information about this topic, please visit our website on \u003ca style=\"color: rgb(0, 0, 0);\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/partica-la-960v2-1944\/\" title=\"Link to HORIBA Partica LA-960V2 webpage\"\u003ePartica LA-960V2 Laser Scattering Particle Size Distribution Analyzer - HORIBA\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":51513246843207,"sku":"","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/files\/3012317055_Dry_chute_LA-950_goulotte_Feed_chute_-1-Photoroom.png?v=1745908038"},{"product_id":"powderjet-dry-feeder-unit-3201081460","title":"PowderJet Dry feeder Unit #3201081460","description":"\u003ch2\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003e\u003cspan data-teams=\"true\"\u003ePowderJet Dry feeder Unit (LY-9705)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003eSystem for PARTICA. SLS (Static Light Scattering) and DIA (Dynamic Imaging Analysis)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0.1-3000µm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003eCan be extended up to 5000µm with the free fall dispersion cell unit\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003eCan be upgraded after the installation of LA main unit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003e2pcs Dry cell windows included (3014043309)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003e1 day of installation\/training must be added\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\" data-teams=\"true\"\u003eThe Dry Powder Feeder Unit can measure samples in a powder state.\u003cbr\u003eIt supports both non-dispersed measurement by free fall and forced-dispersion measurement using compressed air.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003e\u003cspan data-teams=\"true\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIf you want more information about this topic, please visit our website on \u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to HORIBA Partica Laser Difraction and Dynamic Imaging Particle Size and Shape Analyzer Webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/partica-6701\/\"\u003ePartica Laser Diffraction and Dynamic Imaging Particle Size and Shape Analyzer - HORIBA\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":53802792517959,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/files\/4p__Partica_03_1_-Copie.jpg?v=1777372286"},{"product_id":"mini-flow-3201092721","title":"Mini-Flow #3201092721","description":"\u003ch2\u003e\n\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003eMini-Flow \u003cspan style=\"font-size: 10.0pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-ansi-language: FR; mso-fareast-language: FR; mso-bidi-language: AR-SA;\"\u003e(LY-9702)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-ansi-language: FR; mso-fareast-language: FR; mso-bidi-language: AR-SA;\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eSmall volume recirculation unit with ultrasonics (LY-9702) for \u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store Partica Webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica\"\u003ePARTICA\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eSLS (Static Light Scattering) and DIA (Dynamic Imaging Analysis)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eDispersing Volume: \u003c\/strong\u003efrom 35mL to 55mL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eUseful for very small amount of samples or precious samples that requires recovery after measurement\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eSolvant compatible\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCan be upgraded after the installation of LA main unit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eNot compatible with \u003ca style=\"color: rgb(0, 0, 0);\" href=\"https:\/\/store.eu.horiba.com\/products\/ly-9610-imaging-unit-accessory\" title=\"Link to The HORIBA Store Imaging Unit Accessory webpage\"\u003eimaging accessory\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIncluded Standard Flow Cell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\n\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e1 day of installation\/training must be added\u003c\/span\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Tahoma',sans-serif; mso-fareast-font-family: Aptos; mso-fareast-theme-font: minor-latin; mso-ansi-language: FR; mso-fareast-language: FR; mso-bidi-language: AR-SA;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(71, 140, 208);\"\u003e\u003cstrong\u003e\u003cspan data-teams=\"true\"\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-970 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-970\"\u003ePartica LA-970\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to The HORIBA Store LA-1000 webpage\" href=\"https:\/\/store.eu.horiba.com\/collections\/partica-la-1000\"\u003ePartica LA-1000\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIf you want more information about this topic, please visit our website on \u003ca style=\"color: rgb(0, 0, 0);\" title=\"Link to HORIBA Partica Laser Difraction and Dynamic Imaging Particle Size and Shape Analyzer Webpage\" href=\"https:\/\/www.horiba.com\/int\/scientific\/products\/detail\/action\/show\/Product\/partica-6701\/\"\u003ePartica Laser Diffraction and Dynamic Imaging Particle Size and Shape Analyzer - HORIBA\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"The HORIBA Store","offers":[{"title":"Default Title","offer_id":53802933584199,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/files\/25C_0101_miniflow-Photoroom_ce50dc1e-e261-4b15-b0a5-55148fe49806.png?v=1777377140"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0468\/3848\/1057\/collections\/particles_hero_lg2_058f86e6-41c0-48c2-84e9-f961d1715e78.png?v=1777371193","url":"https:\/\/store.eu.horiba.com\/collections\/partica-la-970.oembed","provider":"The HORIBA Store","version":"1.0","type":"link"}